Type l vent installation
Selected components are also available in a powder-coat black finish. AmeriVent Pellet Vent has a lifetime warranty. This system is proudly presented by American Metal Products, a leader in the venting industry for more than fifty years.
This experience is one more reason why we can point with pride to a reputation for unsurpassed product excellence and dependability.
AmeriVent Type B gas vent is used for venting all Category 1 listed gas appliances having draft hoods and other appliances listed to be used with Type B Gas Vent. For information on venting unlisted gas appliances or appliances burning solid or liquid fuels, request our All- Fuel Chimneys catalog. Type B Vent Gas. To Disconnect: Simply realign the seams and pull apart. Product Description The Type B designation is assigned to gas venting systems that meet the safety requirements of Underwriters Laboratories, Inc.
Double-Wall Construction Double-wall metal construction provides protection for health and safety, as well as benefits of economy, ease of installation, efficiency, and protection from property damage. Code calculators: Code Calculators automatically generates a detailed list of requirements. Sign in. P Add Comment. Connectors shall be used to connect fuel-burning appliances to a vertical chimney or vent except where the chimney or vent is attached directly to the appliance.
Vent and chimney connectors shall be installed in accordance with the manufacturer's instructions and within the space where the appliance is located.
Appliances shall be located as close as practical to the vent or chimney. Connectors shall be securely supported and joints shall be fastened with sheet metal screws or rivets. Devices that obstruct the flow of flue gases shall not be installed in a connector unless listed and labeled or approved for such installation. Connectors for oil-fired appliances listed and labeled for Type L vents , passing through walls or partitions shall be in accordance with the following: Type L vent material for oil appliances shall be installed with not less than listed and labeled clearances to combustible material.
Single-wall metal pipe shall be guarded by a ventilated metal thimble not less than 4 inches mm larger in diameter than the vent connector. Not less than 6 inches mm of clearance shall be maintained between the thimble and combustibles. The horizontal run of an uninsulated connector to a natural draft chimney shall not exceed 75 percent of the height of the vertical portion of the chimney above the connector. See Figure 2. Safety concerns are of primary importance with any heating system and should be with direct vented applications.
As previously stated, air flow proving switches are typically used to ensure proper draft from the induced draft fan. Temperature sensing switches can be utilized as back-up protection for a blocked vent condition.
Through-the-wall fittings must be designed for walls constructed of combustible materials. Reliable operation is a second concern. Wind direction and velocity can have a great impact on a side wall exhaust vent and must be considered both in system design and in installation. A closed air system with outside intake on the same wall as the exhaust vent will tend to reduce this problem.