Vcenter converter standalone the specified parameter was not correct




















Workaround: Manually uninstall Converter Standalone agent from the source machine and create a new conversion task. Converter Standalone worker process stops responding if you try to copy a configuration job during guest operating system customization If you right-click a running configuration job and select Copy As New while the destination machine is being customized, Converter Standalone worker process stops responding.

Workaround: Wait for the configuration job to complete before you copy it. Subsequent P2V conversions of remote source machines that run bit Windows Vista or later might fail after a successful conversion If you convert successfully a remote source machine that runs bit Windows Vista, Windows Server , or Windows 7 operating system and then try converting it again, the conversion fails with the error message Converter Standalone Agent installation failed on x.

This error message might occur if automatic uninstall of remote Converter Standalone agent has been enabled during the first successful conversion. Workaround: Restart the remote source machine and try running the conversion task again.

Converter Standalone does not preserve disabled network adapters during conversion of physical machine sources that run on Windows During P2V conversion of Windows source machines, Converter Standalone does not detect disabled network adapters on the source and does not preserve them on the destination virtual machine. Workaround: On the Options page of the Converter Standalone wizard, click Networks to add network adapters to the destination virtual machine.

Microsoft Windows Vista reboots repeatedly after customization Providing wrong customization information might cause the destination virtual machine to reboot repeatedly if the source operating system is Microsoft Windows Vista. During conversion or configuration, if you choose to customize Microsoft Windows Vista and provide wrong customization information, for example an invalid serial key, the customized destination reboots repeatedly.

This is a known issue with Microsoft Windows Vista. Workaround: Make sure that the provided customization information is valid. Converter Standalone remote agent does not notify the user about Converter 3. This prevents older Converter versions from converting this source machine later. Previous Converter versions cannot convert source machines that have Converter Standalone 6.

If Converter Standalone 6. Therefore, you cannot use previous Converter versions to convert sources that have already been converted with Converter Standalone 6. Workaround: Uninstall Converter Standalone 6. Stopping Converter Standalone processes during file-level cloning might cause the machine that runs the Converter Standalone server service to restart During file-level cloning of source systems that run Windows XP or Windows Server , if any of the following Converter Standalone process is forcibly stopped, the machine on which the stopped process was running might automatically reboot.

Workaround: Do not stop any Converter Standalone services on the source machine during file-level cloning. As a result, the destination virtual machine might not boot or might fail to perform as expected. Owner name and organization are not displayed properly after customizing the guest operating system After customizing the guest operating system, Unicode characters used for owner name and organization on the Computer Information page do not appear the way they were set in the Conversion or the Configuration wizard.

For all Windows operating systems except Windows Vista, customization parameters such as user name and organization must use characters only from the local encoding of the default user profile of the guest. For example, you can use Japanese characters for the user name only on a guest whose default user profile's local encoding is set to Japanese.

Earlier versions of Windows use the sysprep. Converter Standalone agent does not start automatically after reboot If the source machine starts up too slowly, Converter Standalone agent might not start automatically after the source machine is restarted. Workaround: Start the Converter Standalone agent manually:.

The source virtual machine does not have the appropriate drivers The following error message appears in the log file when reconfiguration fails because the appropriate drivers are missing from the source operating system: Unable to find symmpi. Sysprep deletes drive letter mappings during customization If you choose customization options and the destination virtual machine fails at a Please Wait screen after the second sysprep reboot, you need to rerun the conversion task without customization.

This issue occurs because of a problem with Microsoft sysprep, which deletes the drive letter mappings, preventing access to certain files. You cannot import a Windows source with "signature " in the boot. If you import a Windows live source with "signature " in the boot. If you try to convert the source without reconfiguration, the conversion succeeds but the destination cannot boot.

Restart the network service. The following warning message appears: GdmLocalIDisplayFactory: maximum number of X display failures reached: check X server log for errors. Workaround: Recreate the xorg. X Server might fail to start in destination virtual machines converted from sources that run Linux When the destination virtual machine starts, X server might fail to start with an error Fatal X server Error.

This is due to incompatibility issues between the display driver used in the Linux source and the display adapter of the destination VMware virtual machine.

Workarounds: Install VMware Tools on the destination virtual machine. Configure the X server on the destination virtual machine to change the refresh rate and the display resolution. The number of LVM logical volumes per volume group is limited to 12 for powered on Linux sources During the conversion of powered on Linux machines, Converter Standalone converts LVM volume groups into new disks on the destination virtual machine.

Workaround: Move volumes out of the new disk to other destination disks:. By default, the Linux P2V helper virtual machine is powered off when the conversion job finishes Workaround: Manually disable this option in the converter-worker. On the machine where Converter Standalone server runs, browse to the converter-worker. Open the converter-worker. Note: Care should be taken when this option is enabled and the helper VM network is configured to use a static IP address.

After the conversion, the helper VM retains the statically configured IP because it is still running. Thus any subsequent Linux P2V jobs cannot use the same static IP until this helper VM is powered off, or at least has its network interface disabled. This allows users to log in to the helper virtual machine after conversion. Source volumes on top of volume managers other than LVM are not recognized during conversion of powered on Linux machines Converter Standalone recognizes only managed source volumes that run on the LVM volume manager.

By default, Converter Standalone has a 20 minute timeout when waiting for the helper virtual machine to start up during Linux P2V conversion This might cause a Linux P2V conversion task to fail due to connection timeout.

Workaround: Extend the timeout period in seconds by modifying the linuxP2VBootTimeout flag in the converter-worker. Note: The timeout value is measured in seconds.

To specify the timeout in minutes, multiply the number of minutes by 60 and use that value. If you change the disk controller type while converting the virtual machine, the destination virtual machine might not boot. Workaround: Configure the destination virtual machine manually. At the minimum, change the root device name to reflect its new name in the destination virtual machine. To make your system more robust, use the volume label or UUID instead of the block device name.

After the conversion is complete, you can rename the virtual machine. The Converter Standalone 6. See Platforms. VMware vCenter Converter Standalone 6. Benefits Convert physical machines running Windows or Linux operating systems to VMware virtual machines quickly and without any disruption or downtime. Enable centralized management of remote conversions of multiple physical servers or virtual machines simultaneously.

Ensure conversion reliability through quiesced snapshots of the guest operating system on the source machine before data migration. Enable non-disruptive conversions through hot cloning, with no source server downtime or reboot. Top of Page Prior Releases of Converter Standalone Features from prior releases of Converter Standalone are described in the release notes for each release.

To view release notes for prior releases of Converter Standalone, click one of the following links: VMware Converter 6. A Save As dialog box appears. Workarounds: Verify that the source virtual machine is powered off prior to conversion.

Provide write privileges to the network share where the source virtual machine resides. Converting standalone VMware sources with a VMDK file greater than 2GB to a hosted destination that resides on a network share that does not support large files, fails If you select a standalone virtual machine source with VMDK file greater than 2GB and try to convert it to hosted destination residing on a remote network location that does not support large files for example, Linux SMB or NFS share , the conversion job might fail with one of following error messages: Unable to connect to the virtual disk Remote server closed connection after 0 response bytes read An error occurred during an operation on a virtual disk If conversion is successful, the following error message related to the VMDK file might appear when you power on the destination virtual machine: Internal Inconsistency errors Workaround: In the main application window of Converter Standalone, right-click the failed job and select Copy As New Wanted to copy and paste text between your pc and a vm?

Now you can. Power off your VM. The vmware performance monitor says that Cannot make a new resource pool or new vApp : grayed out. Unable to make a new resource pool or Vapp? Enable DRS Now we can make new resour Powercli : get list of powered off virtual machines and date of shut down. Vmware DRS anti affinity rules wont let you enter maintenance mode for a esxi host. You have a DRS rule that specifies that 2 vms need to be kept apart: In this case: FT and sql3 For larger clusters with multiple Good for Enterprise problems sending emails to my phone :.

Good for Enterprise problems sending emails. So you have a raw disk mapping on your virtual machine in esxi and you wanted to convert it from a rdmp to a rdmv.

Using the VMware cli Categories 5. Can you storage vmotion svmotion your virutalize Network configuration not updated in configuration There are issues communicating with the following The machine is on tho, so I'm not sure if that's why. You would then need to expand the disk using Windows Disk Management.

I would suggest downloading the VMware Converter and convert the machine. You will have the opportunity to change your disk configuration during the conversion.

What if the exchange on this machine is in coexistence with ? Won't another with the same SID cause issues? Or will it not matter since I'll power the original down first before booting up the new one? I just know that when you clone a DC it causes issues, so I wasn't sure if it would be an issue with Exchange. Have you considered just adding another disk to the VM?

If this is primarily a disk space issue, you could very easily add another disk and move the Exchange data to the new drive using the management shell cmdlets. I can't add another disk because the disk that's the problem is the local disk for the vm. Unless that doesn't matter? I'm still unsure if I should be powering on a clone of our second exchange server on the network. I suspect there is some incompatibility between Workstation and ESXi - for some reasons Workstation thinks that the VM's disk is stored in multiple files which is not possible on VMFS datastore we are not talking about snapshots now.

There used to be official vSphere clients for Win and Mac to manage standalone ESXi servers, but looks like they are not available anymore on the VMware site. I have it installed on my Mac and it works just fine, but I don't have.

Installing a. I don't want to do that. Thanks though, vmnomad. To continue this discussion, please ask a new question. Get answers from your peers along with millions of IT pros who visit Spiceworks. Best Answer. Acronis appears to have worked, and I agree with you that this path was not the greatest



0コメント